Manual Chapter :
Troubleshooting Diameter
Applies To:
Show VersionsBIG-IP LTM
- 15.0.1, 15.0.0
Troubleshooting Diameter
Advanced protocols license
For the BIG-IP system version 12.1 and newer, there is no requirement
for an additional license.
For the BIG-IP system versions 11.6 and 12.0, MRF Diameter virtual
servers will not start unless you have the Advanced Protocols license with the LTM
license.
There is a license check when loading a configuration. The
co/var/log/ltm
file contains a line for "MESSAGE ROUTING DIAMTER feature not licensed."
The license check is only when loading a configuration; no additional message displays
when trying to connect to a virtual server.