The LEDs located on the 1200W DC power supply units (PSUs) indicate PSU operating state.
Input LED
Output/Fault LED
Condition (PWR-0385-xx)
green solid
green solid
Normal operation
off
off
Fault: Input UV
off
amber/yellow solid
Not valid
green solid
amber/yellow solid
Warning: VSB OC
Fault: Fan, OTP, OC, VOUT OV/UV
green solid
amber/yellow blinking
Warning: FAN, OTP, OC, VOUT OV/UV
green blinking
amber/yellow solid
Fault: Input OV
green blinking
amber/yellow blinking
Warning: Input OV, Input UV
green blinking
off
Not valid
green solid
green blinking
PS_ON is high
green solid
off
PS_KILL PSU not inserted