Manual Chapter :
Installation for systems running BIG-IP software on TMOS
Applies To:
Show VersionsInstallation for systems running BIG-IP software on TMOS
Verify the f5optics version on systems running BIG-IP software
You can use
tmsh
to verify the version of the f5optics
package on your system running BIG-IP software and update it to a newer version, if needed.- Connect to the system using the serial console or by opening an SSH session to the management IP address.
- Log in to the command line interface (CLI) of the system using an account with root access.
- Verify the package version.tmsh show net f5opticsThis is an example of the output that you might see when you run this command on a BIG-IP system:Name : f5optics Relocations: (not relocatable) Version : 1.0.0 Vendor: (none) Release : 60.0 Build Date: Wed 13 May 2020 12:29:48 AM PDT Group : System Environment/Libraries Source RPM: f5optics-1.0.0-60.0.src.rpm Summary : F5 optics configuration Description : f5 Optics ConfigurationThis is an example of the output that you might see when you run this command on a VIPRION system:=== slot 2 addr 192.0.2.11 color green === Name : f5optics Relocations: (not relocatable) Version : 1.0.0 Vendor: (none) Release : 60.0 Build Date: Wed 13 May 2020 12:29:48 AM PDT Group : System Environment/Libraries Source RPM: f5optics-1.0.0-60.0.src.rpm Summary : F5 optics configuration Description : f5 Optics Configuration
If the version of
f5optics
on your system is not the latest available from F5, you download the latest version of the package from the F5 Downloads site at my.f5.com/manage/s/downloads.Download the f5optics package
Before you install the optics-mgr-package, you
must download the
f5optics
package.- On your management workstation, log in to MyF5 Downloads.For information about downloading software from MyF5 Downloads page, refer to K000090258: Download F5 products from MyF5.
- Read the End User License Agreement and Program Terms and select the check box.You must accept the license agreement and program terms before you can proceed.
- ClickNext.
- UnderSelect a product family, selectF5OSforGroup.
- UnderTell us more about your product, forProduct Line, selectComponents.
- ForProduct Version, selectoptics-mgr.
- UnderSelect a product container, select the software that you want to download.
- UnderSelect a download file, select the file.
- ForDownload locations, select a download location.
- ClickDownload.
- Download the corresponding checksum file and README file.The corresponding checksum file has the same name, except that.md5is the file extension. After the download completes, verify the integrity of the file by checking the MD5 checksum. For information about verifying MD5 checksum on the downloaded file, refer to K8337: Verifying the MD5 checksum for the downloaded F5 software file.
After you download the latest version of the
f5optics
package, you import the
IMG file to your system and then install the package.Install the f5optics package on BIG-IP systems
Before you can install a new version of the
f5optics
package, you must use SCP to move the f5optics
IM file to the /shared/f5optics/images
directory on your BIG-IP or VIPRION system.You can use
tmsh
to install updates to F5-branded transceiver modules using the f5optics
package. When you run an optics package installation process, traffic on the system being updated is disrupted. During the installation process, you are prompted to confirm that you are aware of this action before the installation can proceed.
- Connect to the system using the serial console or by opening an SSH session to the management IP address.
- Log in to the command line interface (CLI) of the system using an account with admin access.
- Open the TMOS Shell (tmsh).tmsh
- Change to the network module.netThe system prompt updates with the module name:user@bigip01(Active)(/Common)(tmos.net)#
- Install thef5opticspackage.install f5optics [recovery] [slot[ <slot-number> |all] ]Theslotoption applies only to chassis-based systems. Therecoveryoption enables you to recover from a corruptedf5opticsinstallation by installing the latest version of thef5opticspackage that is currently available on the system.
- When you are prompted to confirm the installation, entery.A summary similar to this example displays:Before installation: f5optics-1.0.0-56.0.i686 f5optics-1.0.0-56.0.x86_64 already installed. Installing f5optics-1.0.0-60.0.i686.rpm f5optics-1.0.0-60.0.x86_64.rpm After installation: f5optics-1.0.0-60.0.i686 f5optics-1.0.0-60.0.x86_64 is installed. Restarting bcm56xxd