250W AC power supply unit (PSU) LEDs
The LEDs located on 250W AC power supply units
(PSUs) indicate PSU operating state.
Input LED | Output LED | Condition (PWR-0334-xx) |
---|---|---|
green solid | green solid | Normal operation |
off | off | Fault: Input UV |
off | amber/yellow solid | Not valid |
green solid | amber/yellow solid | Warning: VSB OC Fault: SC, OC, VOUT
OV/UV |
green solid | amber/yellow blinking | Warning: VOUT OC, VOUT OV/UV Fault: VSB OC, VSB SC |
green blinking | amber/yellow solid | Fault: Input OV |
green blinking | amber/yellow blinking | Warning: Input OV, Input
UV |
green blinking | off | Not valid |
green solid | green blinking | PS_ON_L is high |
green solid | off | PS_KILL PSU not inserted |
OV - Over Voltage; OTP - Over Temperature
Protection; UV - Under Voltage; OC - Over Current; VSB - Standby Voltage