System Controller Management
System controller overview
A
VELOS
chassis contains a redundant pair of system
controllers. Together, the system controllers provide a high bandwidth interconnect
between blades, as well as external management connectivity to the blades. Each system
controller has a front-panel serial console and a front panel Ethernet management port.
System controllers operate in an active-active state when routing traffic between
blades, but otherwise operate in a active-standby state for management functions.During initial configuration, you assign these three
management IP addresses to the system controllers:
- Floating IP address
- System controller 1 management IP address
- System controller 2 management IP address
The floating IP address should be the primary management address
for the system, so that connections go to the active system controller. You
can use the floating IP address to manage the system from the webUI, system
controller CLI, or REST APIs. In some cases, such as for troubleshooting, you
might log in to an individual system controller IP address, as opposed to the
floating IP address.
System controller high availability overview
The system controllers are designed to work together as a redundant, high
availability pair.
One of the system controllers is designated as active (or the primary node)
and the other as standby. The system controllers act as an active-standby pair for
system management and as an active-active pair with regard to traffic processing on the
backplane. Each system controller handles half of the traffic in the chassis; if a
system controller is not available, the available bandwidth of the chassis is halved.
Centralized management functions include hosting the primary (floating) IP address and
providing the webUI, CLI, and REST API interfaces that you use to configure and manage
the
VELOS
system.The default mode for system controller high availability (HA) is Auto, which
lets the system select the system controller that is best suited at the time to be the
active system controller. This is the recommended setting.
It is possible to set a preference for either system controller to be
active, however, this should rarely be necessary. When you do specify a preference for a
particular system controller, that system controller will become active if it is in a healthy
operational state. If the preferred controller is not present or unhealthy, the
non-preferred system controller becomes active. When the preferred system controller
returns to an available state, a switchover occurs.
Configure high availability for the system controllers
from the webUI
You should not need to change system
controller high availability (HA) to something other than the default
configuration (Auto), but you can opt to change the configuration or initiate
a failover from the active controller to the standby from the system
controller webUI.
- Log in to the VELOS system controller webUI using an account with admin access.
- On the left, click.
- For thePreferred Nodefield, selectSystem Controller 1orSystem Controller 2to act as an active system controller, or chooseAuto(recommended).Changing the Preferred Node configuration creates a failover event and ends the session if you select the system controller that is currently acting as the standby. Wait 30 seconds and then start a new session with either the floating IP address or the active system controller IP address after the change has completed.Hardware health conditions of the system controllers always take precedence. If one of the system controllers is not healthy, the chassis partition will ignore the preference and synchronize with the healthy system controller.
- To force a failover to occur immediately, clickFailover.TheFailoverbutton is available only whenPreferred Nodefield is set toAuto.You would do this only if you want the current standby system controller to become the active system controller.
Show high availability status for the system controllers
from the CLI
You can view the status of system controller high
availability (HA) from the CLI.
- Connect using SSH to the system controller floating management IP address.
- Log in to the command line interface (CLI) of the system controller using an account with admin access.When you log in to the system, you are in user (operational) mode.
- Show the current HA configuration for the system controllers.show system redundancy stateA summary similar to this example displays:syscon-1-active# show system redundancy state system redundancy state mode auto system redundancy state current-active controller-1
Configure high availability for the system controllers from the
CLI
You can change the preferred system
controller high availability (HA) mode from the system controller CLI.
- Connect using SSH to the system controller floating management IP address.
- Log in to the command line interface (CLI) of the system controller using an account with admin access.When you log in to the system, you are in user (operational) mode.
- Change to config mode.configThe CLI prompt changes to include(config).
- Change system controller redundancy to a specified mode.syscon-1-active(config)# system redundancy config mode [auto|prefer-1|prefer-2}These redundancy modes are available:OptionDescriptionautoSystem chooses preferred mode automatically. This is the default value.prefer-1Prefer controller-1 to be active.prefer-2Prefer controller-2 to be active.This example sets controller-1 as the preferred active system controller.syscon-1-active(config)# system redundancy config mode prefer-1
- Commit the configuration changes.commit
System controller software installation overview
The Controller Management screen on the system controller
webUI includes options for updating system controller software.
The Software Install Status screen on the system controller webUI enables you
to monitor the progress of the updates to system controllers and the chassis
partitions software.
For more information about installing or upgrading system controllers, see
VELOS Systems: Installation and Upgrade
at techdocs.f5.com.Update system controller software from the webUI
Before you begin, consider creating a
backup of the system controller configuration before you update the system.
Configuration file backups are stored in
configs/
. To export the
configuration file, use File Utilities or the file export
command. For
more information, see the Back up system
configurations from the webUI
section.Before
you begin, you must also have imported the updated system controller
software image before you can do the update. Go to
to import the software image file.You can update system controller
software while the system is up and running with only a brief interruption
from the system controller webUI. The software update is applied automatically
to the system controllers one at a time in a rolling update. F5 recommends,
however, that you perform the update during a maintenance window.
- Log in to the VELOS system controller webUI using an account with admin access.
- On the left, click.
- In the Update Software section, forUpdate System Controller Software:
- To install a full F5OS-C version release, selectBundled.
- To install F5OS-C and service version releases independently, selectUnbundled.
- ForISO Image, select the full version release ISO image.This field is available whenBundledis selected.
- To enable out-of-service upgrades, you must downgrade to a software version that does not support rolling upgrades (for example, software prior to F5OS-C software version 1.2.0). ClickShow Advanced Options, then forAllow Out-of-Service Upgrades, selectTrue.
- ForBase OS Version, select the F5OS version.This field is available whenUnbundledis selected.
- ForService Version, select the service version release.This field is available whenUnbundledis selected.
- ClickSave.The system displays a confirmation dialog confirming whether to update the system controllers.
- ClickOKto continue with the update.When updating from 1.2.x to a greater release: first, the system updates the standby system controller, reboots it, and then the standby becomes the active system controller. You will have to log in again after the failover occurs. The system then updates the other system controller (now in standby), and no other interruptions occur.F5 recommends updating the system during a maintenance window. Do not perform any configuration operations while the system is being updated.
The system controllers are both
updated. Traffic is interrupted briefly during the failover from one system
controller to the other. If the update is not successful, the system reverts
to the last working software version on both system controllers. You can
monitor the update progress on the
screen.Display software installation status from the webUI
You can view the software
installation status for the system controllers and the chassis partitions from
the system controller webUI.
- Log in to the VELOS system controller webUI using an account with admin access.
- On the left, click.
Software installation status is shown for both
system controllers and the chassis partitions. You can see whether a recent installation was
successful and view what software version is running.
Chassis terminal service overview
With
VELOS
chassis, blades
do not have physical console ports. Each system controller has a physical
console port. The system controllers in the chassis provide a terminal service
that enables authorized users to access blade consoles over SSH using the
chassis floating IP address.At a high level, these user roles have terminal service access:
- Admin
- Users with this role can access any terminals in the chassis.
- Terminal server admin
- Users with this role have terminal server access to all consoles on the system regardless of partition restrictions.
- Operator
- Users with this role can access any terminals in the chassis.
- Partition
- Users with this role are not given access to any terminals in the chassis.
Since the chassis terminal service uses SSHD, clients can connect using SSH. The terminal service uses a range of network port numbers to differentiate between connections being requested to the various consoles in the chassis.
You can also access any blade console by selecting the desired blade using the Always-On Management (AOM) Command Menu after you connect a serial cable to either of the system controllers' console ports. For more information about AOM, see the section entitled
About Always-On Management
in the platform guide for your VELOS
chassis
.Console port numbers
The
VELOS
chassis terminal service uses a range of network port numbers to differentiate
between connections being requested to either the blade or system controller
consoles in a chassis. Console |
Port number |
---|---|
System controller 1 |
7100 |
System controller 2 |
7200 |
Blade < 1...x > |
700x |
Connect to a blade or system controller using the chassis
terminal service
If you are an authorized user, you can
connect to a blade or system controller using the chassis terminal service.
- Connect using SSH to the blade or system controller that you want to access.ssh <blade-or-sys-controller-ip-address> -l admin -p <port-number>This example opens an SSH session to an IPv4 address as an admin user to the blade in slot 1:ssh 192.0.2.10 -l admin -p 7001This example opens an SSH session to an IPv4 address as an admin user to the system controller in slot 2:ssh 192.0.2.10 -l admin -p 7200This example opens an SSH session to an IPv6 address as an admin user to the blade in slot 4:ssh 2001:db8:ffff:100::1 -l admin -p 7004If there is not already an active terminal session attached to the specified console, you are connected immediately. If there is already an active terminal session attached, you can choose to terminate the existing terminal session and replace it.
When you complete your terminal session to a blade
or a system controller, you can terminate your session by typing the
Enter ~.
(tilde period) command
sequence.