Manual Chapter :
Internal Chassis Networking
Applies To:
Show VersionsF5OS-C
- 1.6.1
Internal Chassis Networking
Chassis
NetworkingInternal chassis networking overview
The
VELOS
system uses an internal
chassis network for control plane and management plane communication between
firmware and software on the blades and system controllers. Traffic on this
internal network is firewall-protected and is not exposed to a customer’s
management network.Internal
VELOS
chassis networking can
use one of two IP address ranges known as RFC6598 and RFC1918. The RFC6598
address range maps the predefined VELOS
internal network
range to 100.64/12 IP addresses (the default). The RFC1918 range enables you
choose one of 16 possible address ranges in the 10.0.0.0/12 address range.IP addresses in the predefined range are reserved for the
internal network and cannot be used for any of these addresses:
- VELOSmanagement IP addresses for the system controllers, chassis partitions, and tenants
- Any external service configured on theVELOSsystem, such as a DNS server and NTP server
- Source IP addresses of any device used to communicate with theVELOSsystem (such as a laptop, workstation, or other device that connects)
If your network uses addresses in the default predefined
range for any of the above, you will not be able to access the
VELOS
system using the VELOS
management interfaces (including the CLI, webUI, or REST APIs). This is only
an issue if you use 100.64.0.0/12 addresses for VELOS management IP addresses,
external servers, or source IP addresses described here. To prevent this
issue, F5 provides a procedure that enables you to select a different internal
IP address range during initial provisioning of a system, as an alternative to
using the default range.Change the internal network IP range
The
VELOS
internal
chassis network uses 100.64.0.0/12 addresses. If your network needs to use this range,
you can change the range of IP addresses that the internal chassis network implements.
Instead, you can choose one of 16 possible address ranges in the 10.0.0.0/12 address
range. It is recommended that you make this
change before initial configuration or immediately after.
- If you have not performed initial setup of the system and configured management IP addresses, connect using the management console. If setup is already complete, log in using the floating IP address.
- Log in to the command line interface (CLI) of the system controller using an account with admin access.When you log in to the system, you are in user (operational) mode.
- Change to config mode.configThe CLI prompt changes to include(config).
- Show the network prefix ranges for network range RFC1918.system network config network-range-type RFC1918 prefix ?
- Show the network prefix index ranges.syscon-1-active(config)# system network config network-range-type RFC1918 prefix ? Description: The network prefix index is used to select the range of IP addresses used internally within the chassis. The network prefix should be selected such that internal chassis addresses do not overlap with site-local addresses that are accessible to the chassis. Network Prefix Index Chassis Network Range 0 10.[0-15].0.0/12 1 10.[16-31].0.0/12 2 10.[32-47].0.0/12 3 10.[48-63].0.0/12 4 10.[64-79].0.0/12 5 10.[80-95].0.0/12 6 10.[96-111].0.0/12 7 10.[112-127].0.0/12 8 10.[128-143].0.0/12 9 10.[144-159].0.0/12 10 10.[160-175].0.0/12 11 10.[176-191].0.0/12 12 10.[192-207].0.0/12 13 10.[208-223].0.0/12 14 10.[224-239].0.0/12 15 10.[240-255].0.0/12 Possible completions: <unsignedByte, 0 .. 15>[0]
- Select the network range to use for internal networking (0-15).system network config network-range-type RFC1918 prefix <0-15>This example sets the range to 10.[0-15].0.0/12:syscon-1-active(config)# system network config network-range-type RFC1918 prefix 0
- Commit the configuration changes.commit
- Power cycle the chassis.Changing the internal chassis network causes an automatic cluster reinstall process that takes approximately an hour to complete.
- Check the status of the cluster installation.show cluster install-progressA summary similar to this example displays:syscon-1-active# show cluster install-progress STAGE NAME STATUS --------------------------------- AddingBlade Done HealthCheck Done HostedInstall Done MasterAdditionalInstall Done MasterInstall Done NodeBootstrap Done NodeJoin Done Prerequisites Done ServiceCatalogInstall Done etcdInstall Done
When the install status is
Done
for all stages, you can resume configuring the
system.