Health Engine Actions Reference
When a heuristic script detects a condition on your F5OS platform, it can generate one or more actions. Actions tell you or the system what to do next. Some actions run automatically, while others appear as recommendations for you to act on.
This reference lists all supported actions, their required data fields, and whether the system performs them automatically.
Each action has three properties:
- Value: The action identifier used by the engine.
- Recommend: When
true, the action appears as a recommendation only and does not run automatically. Actions that could affect system performance or operation are always recommendations. Whenfalse, the system can perform the action automatically. - Data fields: Additional information the heuristic script must provide when it generates the action.
You can view all current recommendations through the confd CLI:
show system health recommendations nodes node recommendationGenerate an F5OS confd alarm. The alarm appears in the show system alarms API.
| Property | Value |
|---|---|
| Value | generate-alarm |
| Recommend | false |
| Data fields | alert (string), source (string) |
Behavior:
- If the alarm is already asserted, a repeated generate does not re-assert it.
Clear an asserted F5OS confd alarm.
| Property | Value |
|---|---|
| Value | clear-alarm |
| Recommend | false |
| Data fields | alert (string), source (string) |
Behavior:
- If the alarm is not asserted, a repeated clear is a no-op.
Generate an F5OS confd event. The event appears in the show system events API.
| Property | Value |
|---|---|
| Value | generate-event |
| Recommend | false |
| Data fields | alert (string), source (string) |
Recommend that a platform reboot be performed.
| Property | Value |
|---|---|
| Value | platform-reboot |
| Recommend | true |
| Data fields | node (string) |
Recommend that a platform shutdown be performed.
| Property | Value |
|---|---|
| Value | platform-shutdown |
| Recommend | true |
| Data fields | node (string) |
Recommend that a VELOS chassis system controller failover be performed.
| Property | Value |
|---|---|
| Value | trigger-failover |
| Recommend | true |
| Data fields | None |
Recommend that a specific service be restarted.
| Property | Value |
|---|---|
| Value | service-restart |
| Recommend | true |
| Data fields | service (string) |
Recommend that a service log level be updated.
| Property | Value |
|---|---|
| Value | log-level |
| Recommend | true |
| Data fields | service (string), severity (string) |
Recommend that a qkview capture be performed.
| Property | Value |
|---|---|
| Value | qkview-capture |
| Recommend | true |
| Data fields | file (string) |
Update the health of a diag-agent component or attribute.
| Property | Value |
|---|---|
| Value | update-health |
| Recommend | false |
| Data fields | component (string), value (any) |
Optional fields: attribute, severity
Recommend that a node be replaced.
| Property | Value |
|---|---|
| Value | replace-node |
| Recommend | true |
| Data fields | node (string) |
A node can be a blade or controller.
Recommend that a hardware component be replaced.
| Property | Value |
|---|---|
| Value | replace-component |
| Recommend | true |
| Data fields | None |
A component can be an LCD, fan tray, Power Supply Unit (PSU), PSU controller, or drive.
No action. Used when a heuristic completes without generating an actionable recommendation.
| Property | Value |
|---|---|
| Value | none |
| Recommend | true |
| Data fields | None |
| Action | Automatic | Recommended only | Required data fields |
|---|---|---|---|
generate-alarm |
✅ | alert, source |
|
clear-alarm |
✅ | alert, source |
|
generate-event |
✅ | alert, source |
|
platform-reboot |
✅ | node |
|
platform-shutdown |
✅ | node |
|
trigger-failover |
✅ | None | |
service-restart |
✅ | service |
|
log-level |
✅ | service, severity |
|
qkview-capture |
✅ | file |
|
update-health |
✅ | component, value |
|
replace-node |
✅ | node |
|
replace-component |
✅ | None | |
none |
✅ | None |