Applies To:
Show VersionsBIG-IP AAM
- 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP APM
- 15.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP GTM
- 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP Link Controller
- 15.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP Analytics
- 15.0.0
BIG-IP LTM
- 15.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP PEM
- 15.0.0
BIG-IP AFM
- 15.0.0
BIG-IP DNS
- 15.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0
BIG-IP ASM
- 15.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
Platform Installation
About platform installation
After you have reviewed the hardware requirements and become familiar with the 11050 platform, you can install the unit.
Determining which rack mounting kit to use
The 11050 platform comes with two types of rack mounting kits: stationary front-mounting and sliding rail-mounting. An advantage of installing the sliding rail-mounting kit is that you can then slide the unit in and out of the rack as needed.
The 11050 NEBS platform comes with three types of rack mounting kits: a four-point mount kit, a center-mount kit for 19-inch telco-style (two-post) racks, and a center-mount kit for 23-inch telco-style (two-post) racks.
The tasks required to install the platform differ depending on the type of rack mount you decide to use or which type of cabinet unit you are installing into (single two-post cabinet or four-post cabinet).
About general recommendations for rack mounting
Although not required, a 1U space between units makes it easier for you to remove the unit from the rack if that the unit requires service. A 1U space between units also provides additional cable routing options.
Leaving at least 100 mm spacing from the front panel of the unit to the rack front or rack door provides enough room for you to route the cables without excessive bending or insulation damage.
About the front-mounting kit
You can use the front-mounting kit if you are installing into a two-post rack.
Front-mounting kit hardware
The front-mounting kit includes these parts.
Quantity | Hardware |
---|---|
2 | front-mounting brackets |
10 | M4 x 10mm flat head screws |
4 | M4 finishing washers |
Installing using a front-mounting kit
About the four-point rack mounting kit
You can use the four-point rack mounting kit if you are installing the 11050 NEBS platform into a four-post rack or cabinet.
Four-point rack mounting kit hardware
The four-point rack mounting kit includes these parts.
Quantity | Hardware |
---|---|
2 | front-mounting brackets (left and right) |
2 | rear-mounting brackets (left and right) |
1 | rear-mount support bracket |
16 | M4 x 8mm SEMS screws |
6 | M4 x 10mm flat head screws |
Installing using a four-point rack mounting kit
About the center-mounting kits
You can use a center-mounting kit if you are installing into a 19-inch or 23-inch telco-style (two-post) rack.
If you are installing the 11050 NEBS platform into a 19-inch telco-style rack, you use the smaller set of center-mounting brackets.
Center-mounting brackets for 19-inch rack
If you are installing the 11050 NEBS platform into a 23-inch telco-style rack, you use the larger set of center-mounting brackets.
Center-mounting brackets for 23-inch rack
Center-mounting kit hardware
The center-mounting kit includes these parts.
Quantity | Hardware |
---|---|
2 | center-mounting brackets for 19-inch rack |
2 | center-mounting brackets for 23-inch rack |
12 | M4 x 8mm SEMS screws |
Installing to a 19-inch rack using a center-mounting kit
Installing to a 23-inch rack using a center-mounting kit
About the quick-install rail kit
Use the quick-install rail kit if you want to be able to slide the unit in or out of the rack for maintenance activities.
The kit includes the following hardware:
- two rails (left and right)
- eight #8-32 thumb screws
The rails snap into place in the rack, and no tools are required to install a platform using this kit. The rails are optimized for installation into square hole cabinets, but they can be installed in other cabinet styles, such as round hole cabinets, using the screws provided. The rails are easily converted to mount to either cabinet style.
Quick-install rail kit
For information about installing the platform using the quick-install rail kit, see the instruction guide provided by the manufacturer, which is included with the kit hardware.
An example of a platform installed using the quick-install rail kit
After installing the platform, you should secure it to the rack using the included rail locks. You should also attach the front bezel to the unit by grasping the bezel on either side using the indentations provided.
Connecting the cables and other hardware
After you have installed the unit into the rack, connect the cables and other hardware.
You can now assign a management IP address to the system, and then license and provision the software.
Optionally, you should run the latest version of the qkview utility. This utility collects configuration and diagnostic information about your system into a single file that you can provide to F5 Technical Support to aid in troubleshooting. For more information, see http://support.f5.com/kb/en-us/solutions/public/1000/800/sol1858.html.
Configuring a management IP address
- Press the X button to activate Menu mode for the LCD.
- Use the arrow keys to select System, and then press the Check button.
- Press the Check button to select Management.
- Press the Check button to select Mgmt IP.
- Enter your management IP address using the up and down arrow keys, and then press the Check button.
- Use the arrow keys to select Mgmt Mask, and then press the Check button.
- Enter the netmask using the up and down arrow keys, and then press the Check button.
- Use the arrow keys to select Mgmt Gateway, and then press the Check button.
- Enter your default route using the up and down arrow keys, and then press the Check button. If you do not have a default route, enter 0.0.0.0.
- Use the arrow keys to select Commit, and then press the Check button.
- Press the Check button to select OK.