General specifications for system features

This table lists general specifications for the VIPRION® 2400 platform.

Item Specification
Transceiver modules hot swap Support for hot swap of transceiver modules
Dynamic routing protocols BFD, BGP4, IS-IS, OSPFv2, OSPFv3, RIPv1/RIPv2, RIPng
Jumbo frames Support for maximum Ethernet frame size of 9216 bytes and MTU of 9128 bytes
Virtual Clustered Multiprocessing™ (vCMP™) Supports provisioning and managing multiple, hosted instances of the BIG-IP software on a single hardware device
Important: Specifications are subject to change without notification.

Blade hardware specifications

This table lists hardware specifications for VIPRION B2000 Series blades.

Specification B2100 B2150 B2250
Dimensions Proprietary to fit F5 Networks chassis
Weight 9.5 pounds (4.3 kg) 9.5 pounds (4.3 kg) 10.0 pounds (4.5 kg)
Processor 1 x Quad-Core Intel® Xeon® processor (total 8 hyperthreaded logical processor cores) 1 x Quad-Core Intel® Xeon® processor (total 8 hyperthreaded logical processor cores) 1 x 10-Core Intel® Xeon® processor (total 20 hyperthreaded logical processor cores)
Communication interfaces 8 x 1GbE/10GbE SFP+ fiber ports

1 x 10/100/1000 Ethernet Management port

1 x RJ45 console port

1 x RJ45 failover port

2 x USB 2.0 interfaces

8 x 1GbE/10GbE SFP+ fiber ports

1 x 10/100/1000 Ethernet Management port

1 x RJ45 console port

1 x RJ45 failover port

2 x USB 2.0 interfaces

4 x 40GbE QSFP+ fiber ports

1 x 10/100/1000 Ethernet Management port

1 x RJ45 console port

2 x USB 2.0 interfaces

Hard drive capacity

1 x 300 GB hard disk drive (HDD)

1 x 400 GB solid-state drive (SSD) 1 x 800 GB SSD
RAM 16 GB 32 GB 64 GB
Important: Specifications are subject to change without notification.
Important: F5® only provides support for F5-branded or F5-provided optical modules.

Chassis hardware specifications

This table lists hardware specifications for the VIPRION® 2400 chassis.

Item Specification
Dimensions H: 6.89 inches (17.5 cm) x W: 17.64 inches (44.8 cm) x D: 21.18 inches (53.8 cm) rack-mount chassis
Weight

Fully-loaded system (4 blades, 2 power supplies, 1 fan tray): 95.5-97.5 pounds (43.3-44.2 kg)

Half-loaded system (2 blades, 2 power supplies, 2 blank line cards, 1 fan tray): 77.5-78.5 pounds (35.2-35.6 kg)

Empty chassis (3 blank line cards, 0 power supplies, 0 blades, 1 fan tray): 42.5 pounds (19.3 kg)

Power supply: 7.5 pounds (3.4 kg)

B2100 blade: 9.5 pounds (4.3 kg)

B2150 blade: 9.5 pounds (4.3 kg)

B2250 blade: 10.0 pounds (4.5 kg)

Blank line card: 0.5 pounds (0.2 kg)

Fan tray: 6.5 pounds (2.9 kg)

Processor See blade specifications
Hard drive capacity See blade specifications
RAM See blade specifications
AC power input requirements

2 x 100-127 VAC (1200W)/200-240 VAC (1400W) auto-ranging

16A per input line (max)

DC power supply

1 to 2 x 1400W 44 to 65 VDC

44A per input (max)

Important: Specifications are subject to change without notification.

Chassis environmental operating specifications

This table lists environmental operating specifications for the VIPRION® chassis.

Item Specification
Operational temperature 32° to 104°F (0° to 40°C)
Operational relative humidity 5 to 85% at 104°F (40°C)
Non-operational temperature -40 to 158°F (-40 to 70°C)
Non-operational humidity 5 to 95% at 40°C non-condensing
Important: Specifications are subject to change without notification.

About AC power requirements

When working with an AC-powered VIPRION® platform, it is important to understand the AC power options and requirements.

About AC power cables

The power cable supplied with the hardware is a 220V high-line input cable. This type of cable requires a NEMA 6-20R wall outlet or a region-specific equivalent. Region-specific power cables are available from F5® Networks.

Note: The power cables included with this unit are for exclusive use with this unit and should not be used with other electrical appliances.

AC power redundancy provisioning

This VIPRION® platform supports up to two AC power supplies. The power supplies are auto-ranging 100-127VAC (low-line) to 200-240VAC (high-line) input, and can supply 1200W output power at low-line and 1400W output power at high-line. The fan tray is provisioned to draw up to 100W. Each slot is provisioned to draw up to 275W, if needed; therefore, one power supply with low-line input can support one, two, three, or four B2000 Series blades, plus the fan tray with no redundancy. The same supply with high-line input can also support up to four B2000 Series blades. If redundancy is desired in any configuration, simply add the second power supply at either low- or high-line input. This table shows some of the possible blade and power supply redundancy configurations.

  No redundancy 1 + 1 redundancy
Blade type Blade quantity Supplies (low-line) Supplies (high-line) Supplies (low-line) Supplies (high-line)
B2100 1 (350W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
2 (600W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
3 (850W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
4 (1100W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
B2150 1 (350W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
2 (600W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
3 (850W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
4 (1100W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
B2250 1 (350W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
2 (600W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
3 (850W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)
4 (1100W) 1 (1200W available) 1 (1400W available) 2 (2400W available) 2 (2800W available)

AC platform power consumption (low-line input)

The actual amount of power draw from the AC source depends on the type and number of blades, as well as the power supply AC source voltage and redundancy configuration. This table shows possible configurations for low-line voltage, and the typical and maximum power draw.

Blade quantity and type Typical system power draw (W) Maximum system power draw (W) Typical system heat (BTU/hr) Maximum system heat (BTU/hr) Number of power supplies installed
Chassis only < 75 < 100 < 250 < 340 1 or 2
1 x B2100 245 370 840 1265 1
2 x B2100 430 610 1470 2085 1
3 x B2100 615 870 2100 3890 1
4 x B2100 805 1140 2750 3890 1
1 x B2100 275 395 940 1350 2
2 x B2100 455 635 1555 2170 2
3 x B2100 640 885 2185 3020 2
4 x B2100 835 1120 2850 3825 2
1 x B2150 245 370 840 1265 1
2 x B2150 430 610 1470 2085 1
3 x B2150 615 870 2100 2970 1
4 x B2150 805 1140 2750 3890 1
1 x B2150 275 395 940 1350 2
2 x B2150 455 635 1555 2170 2
3 x B2150 640 885 2185 3020 2
4 x B2150 835 1120 2850 3825 2
1 x B2250 275 395 940 1350 1
2 x B2250 480 670 1640 2290 1
3 x B2250 675 960 2305 3280 1
4 x B2250 905 1295 3090 4420 1
1 x B2250 305 420 1045 1435 2
2 x B2250 500 695 1710 2375 2
3 x B2250 695 950 2375 3245 2
4 x B2250 900 1235 3075 4215 2

AC platform power consumption (high-line input)

The actual amount of power draw from the AC source depends on the type and number of blades, as well as the power supply AC source voltage, and redundancy configuration. This table shows possible configurations for high-line input, and the typical and maximum AC mains power draw.

Blade quantity and type Typical system power draw (W) Maximum system power draw (W) Typical system heat (BTU/hr) Maximum system heat (BTU/hr) Number of power supplies installed
Chassis only < 100 < 100 < 340 < 340 1 or 2
1 x B2100 250 360 855 1230 1
2 x B2100 430 605 1470 2065 1
3 x B2100 610 850 2085 2905 1
4 x B2100 800 1090 2730 3720 1
1 x B2100 280 385 960 1315 2
2 x B2100 460 625 1570 2135 2
3 x B2100 635 860 2170 2935 2
4 x B2100 820 1095 2800 3740 2
1 x B2150 250 360 855 1230 1
2 x B2150 430 605 1470 2065 1
3 x B2150 610 850 2085 2905 1
4 x B2150 800 1090 2730 3720 1
1 x B2150 280 385 960 1315 2
2 x B2150 460 625 1570 2135 2
3 x B2150 635 860 2170 2935 2
4 x B2150 820 1095 2800 3740 2
1 x B2250 270 395 925 1350 1
2 x B2250 480 665 1640 2270 1
3 x B2250 675 970 2305 3310 1
4 x B2250 905 1245 3090 4250 1
1 x B2250 305 415 1045 1420 2
2 x B2250 500 690 1710 2355 2
3 x B2250 700 955 2390 3260 2
4 x B2250 900 1245 3075 4250 2

DC power requirements

When working with a DC-powered VIPRION® 2400 platform, it is important to understand the DC power options and requirements.

The platform supports up to two hot swappable DC power supplies. One power supply powers a chassis that contains zero to four blades, with no redundancy. Two power supplies power a chassis with any blade configuration, with full redundancy.

DC platform power consumption

The actual amount of power draw from the DC power source depends on the type and number of blades, and the redundancy configuration. This table shows several possible configurations, and the typical and maximum power draw.

Blade quantity and type Typical system power draw (W) Maximum system power draw (W) Typical system heat (BTU/hr) Maximum system heat (BTU/hr) Number of power supplies installed
Chassis only < 100 < 100 < 340 < 340 1 or 2
1 x B2100 240 335 820 1145 1
2 x B2100 415 555 1420 1895 1
3 x B2100 595 830 2035 2835 1
4 x B2100 775 1085 2645 3705 1
1 x B2100 255 355 875 1215 2
2 x B2100 430 585 1470 2000 2
3 x B2100 605 825 2065 2820 2
4 x B2100 785 1060 2680 3620 2
1 x B2150 240 335 820 1145 1
2 x B2150 415 555 1420 1895 1
3 x B2150 595 830 2035 2835 1
4 x B2150 775 1085 2645 3705 1
1 x B2150 255 355 875 1215 2
2 x B2150 430 585 1470 2000 2
3 x B2150 605 825 2065 2820 2
4 x B2150 785 1060 2680 3620 2
1 x B2250 255 370 875 1265 1
2 x B2250 450 640 1540 2185 1
3 x B2250 645 915 2205 3125 1
4 x B2250 840 1215 2870 4150 1
1 x B2250 270 385 925 1315 2
2 x B2250 465 640 1590 2185 2
3 x B2250 665 895 2270 3055 2
4 x B2250 850 1200 2905 4095 2

Safety requirements

This equipment complies with these safety requirements of the Low Voltage Directive 2006/95/EC.

EC Type Examination Certificates:
  EN 60950-1:2006 + A11:2009  
  IEC 60950-1:2005, 2nd Edition  
  CB Scheme  
  UL 60950-1 2nd Edition, CSA C22.2 No. 60950-1-07 Master Contract: 252302
Important: Specifications are subject to change without notification.

EMC requirements

USA--FCC Class A, Canada--Industry Canada Class A

This equipment complies with Subpart B of Part 15 of FCC Rules for Class A digital devices, Industry Canada ICES-003, Issue 5. Operation is subject to these two conditions:

  • This equipment may not cause harmful interference.
  • This device must accept any interference received, including interference that may cause undesired operation.

European Union

This equipment complies with these requirements of the EMC Directive 2004/108/EC:

As Telecommunication Network Equipment (TNE) in Both Telecom Centers and Other than Telecom Centers per (as applicable):

Directive Required Limits
EN 300 386 V1.5.1 2010    
EN 55022:2006 + C1:2006   Class A
EN 61000-3-2:2006 A1:2009 + A2:2009    
EN 61000-3-3:2008    
  IEC 61000-4-2 6 kV (Direct), 8 kV (Air)
  IEC 61000-4-3 3 V/m 80-1000MHz, 10 V/m 800-960 MHz and 1400-2700 MHz
  IEC 61000-4-4 1 kV AC and DC Power Lines, 0.5 kV Signal Lines
  IEC 61000-4-5 2 kV AC Line-Gnd, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor Signal Lines > 10m.
  IEC 61000-4-6 3 V
  IEC 61000-4-11  

As Information Technology Equipment (ITE) Class A per (as applicable):

Directive Required Limits
EN 55024:2010    
EN 55022:2010   Class A
EN 61000-3:2008    
EN 55024:2010    
  IEC61000-4-2 4 kV (Direct), 8 kV (Air)
  IEC61000-4-3 3 V/m
  IEC61000-4-4 1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines
  IEC61000-4-5 2 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines
  IEC61000-4-6 3 V
  IEC61000-4-11  
Important: Specifications are subject to change without notification.

Acoustic, airflow, and altitude specifications

This table lists acoustic levels, airflow movement, and operational altitude specifications for the VIPRION® 2400 platform.

Specification type Detail Units Chassis with blade
Maximum acoustic output 1 Front

Left

Right

Rear

dBA

dBA

dBA

dBA

75

71

72

81

Altitude 2

Operational

Non-operational

Feet

Feet

6000

40,000

Airflow 3 Entire chassis CFM 581