Applies To:
Show VersionsPlatform Specifications
General specifications for system features
This table lists general specifications for the VIPRION® 2400 platform.
Item | Specification |
---|---|
Transceiver modules hot swap | Support for hot swap of transceiver modules |
Dynamic routing protocols | BFD, BGP4, IS-IS, OSPFv2, OSPFv3, RIPv1/RIPv2, RIPng |
Jumbo frames | Support for maximum Ethernet frame size of 9216 bytes and MTU of 9128 bytes |
Virtual Clustered Multiprocessing™ (vCMP™) | Supports provisioning and managing multiple, hosted instances of the BIG-IP software on a single hardware device |
Blade hardware specifications
This table lists hardware specifications for VIPRION B2000 Series blades.
Specification | B2100 | B2150 | B2250 |
---|---|---|---|
Dimensions | Proprietary to fit F5 Networks chassis | ||
Weight | 9.5 pounds (4.3 kg) | 9.5 pounds (4.3 kg) | 10.0 pounds (4.5 kg) |
Processor | 1 x Quad-Core Intel® Xeon® processor (total 8 hyperthreaded logical processor cores) | 1 x Quad-Core Intel® Xeon® processor (total 8 hyperthreaded logical processor cores) | 1 x 10-Core Intel® Xeon® processor (total 20 hyperthreaded logical processor cores) |
Communication interfaces | 8 x 1GbE/10GbE SFP+ fiber ports 1 x 10/100/1000 Ethernet Management port 1 x RJ45 console port 1 x RJ45 failover port 2 x USB 2.0 interfaces |
8 x 1GbE/10GbE SFP+ fiber ports 1 x 10/100/1000 Ethernet Management port 1 x RJ45 console port 1 x RJ45 failover port 2 x USB 2.0 interfaces |
4 x 40GbE QSFP+ fiber ports 1 x 10/100/1000 Ethernet Management port 1 x RJ45 console port 2 x USB 2.0 interfaces |
Hard drive capacity |
1 x 300 GB hard disk drive (HDD) |
1 x 400 GB solid-state drive (SSD) | 1 x 800 GB SSD |
RAM | 16 GB | 32 GB | 64 GB |
Chassis hardware specifications
This table lists hardware specifications for the VIPRION® 2400 chassis.
Item | Specification |
---|---|
Dimensions | H: 6.89 inches (17.5 cm) x W: 17.64 inches (44.8 cm) x D: 21.18 inches (53.8 cm) rack-mount chassis |
Weight |
Fully-loaded system (4 blades, 2 power supplies, 1 fan tray): 95.5-97.5 pounds (43.3-44.2 kg) Half-loaded system (2 blades, 2 power supplies, 2 blank line cards, 1 fan tray): 77.5-78.5 pounds (35.2-35.6 kg) Empty chassis (3 blank line cards, 0 power supplies, 0 blades, 1 fan tray): 42.5 pounds (19.3 kg) Power supply: 7.5 pounds (3.4 kg) B2100 blade: 9.5 pounds (4.3 kg) B2150 blade: 9.5 pounds (4.3 kg) B2250 blade: 10.0 pounds (4.5 kg) Blank line card: 0.5 pounds (0.2 kg) Fan tray: 6.5 pounds (2.9 kg) |
Processor | See blade specifications |
Hard drive capacity | See blade specifications |
RAM | See blade specifications |
AC power input requirements |
2 x 100-127 VAC (1200W)/200-240 VAC (1400W) auto-ranging 16A per input line (max) |
DC power supply |
1 to 2 x 1400W 44 to 65 VDC 44A per input (max) |
Chassis environmental operating specifications
This table lists environmental operating specifications for the VIPRION® chassis.
Item | Specification |
---|---|
Operational temperature | 32° to 104°F (0° to 40°C) |
Operational relative humidity | 5 to 85% at 104°F (40°C) |
Non-operational temperature | -40 to 158°F (-40 to 70°C) |
Non-operational humidity | 5 to 95% at 40°C non-condensing |
About AC power requirements
When working with an AC-powered VIPRION® platform, it is important to understand the AC power options and requirements.
About AC power cables
The power cable supplied with the hardware is a 220V high-line input cable. This type of cable requires a NEMA 6-20R wall outlet or a region-specific equivalent. Region-specific power cables are available from F5® Networks.
AC power redundancy provisioning
This VIPRION® platform supports up to two AC power supplies. The power supplies are auto-ranging 100-127VAC (low-line) to 200-240VAC (high-line) input, and can supply 1200W output power at low-line and 1400W output power at high-line. The fan tray is provisioned to draw up to 100W. Each slot is provisioned to draw up to 275W, if needed; therefore, one power supply with low-line input can support one, two, three, or four B2000 Series blades, plus the fan tray with no redundancy. The same supply with high-line input can also support up to four B2000 Series blades. If redundancy is desired in any configuration, simply add the second power supply at either low- or high-line input. This table shows some of the possible blade and power supply redundancy configurations.
No redundancy | 1 + 1 redundancy | ||||
---|---|---|---|---|---|
Blade type | Blade quantity | Supplies (low-line) | Supplies (high-line) | Supplies (low-line) | Supplies (high-line) |
B2100 | 1 (350W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) |
2 (600W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) | |
3 (850W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) | |
4 (1100W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) | |
B2150 | 1 (350W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) |
2 (600W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) | |
3 (850W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) | |
4 (1100W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) | |
B2250 | 1 (350W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) |
2 (600W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) | |
3 (850W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) | |
4 (1100W) | 1 (1200W available) | 1 (1400W available) | 2 (2400W available) | 2 (2800W available) |
AC platform power consumption (low-line input)
The actual amount of power draw from the AC source depends on the type and number of blades, as well as the power supply AC source voltage and redundancy configuration. This table shows possible configurations for low-line voltage, and the typical and maximum power draw.
Blade quantity and type | Typical system power draw (W) | Maximum system power draw (W) | Typical system heat (BTU/hr) | Maximum system heat (BTU/hr) | Number of power supplies installed |
---|---|---|---|---|---|
Chassis only | < 75 | < 100 | < 250 | < 340 | 1 or 2 |
1 x B2100 | 245 | 370 | 840 | 1265 | 1 |
2 x B2100 | 430 | 610 | 1470 | 2085 | 1 |
3 x B2100 | 615 | 870 | 2100 | 3890 | 1 |
4 x B2100 | 805 | 1140 | 2750 | 3890 | 1 |
1 x B2100 | 275 | 395 | 940 | 1350 | 2 |
2 x B2100 | 455 | 635 | 1555 | 2170 | 2 |
3 x B2100 | 640 | 885 | 2185 | 3020 | 2 |
4 x B2100 | 835 | 1120 | 2850 | 3825 | 2 |
1 x B2150 | 245 | 370 | 840 | 1265 | 1 |
2 x B2150 | 430 | 610 | 1470 | 2085 | 1 |
3 x B2150 | 615 | 870 | 2100 | 2970 | 1 |
4 x B2150 | 805 | 1140 | 2750 | 3890 | 1 |
1 x B2150 | 275 | 395 | 940 | 1350 | 2 |
2 x B2150 | 455 | 635 | 1555 | 2170 | 2 |
3 x B2150 | 640 | 885 | 2185 | 3020 | 2 |
4 x B2150 | 835 | 1120 | 2850 | 3825 | 2 |
1 x B2250 | 275 | 395 | 940 | 1350 | 1 |
2 x B2250 | 480 | 670 | 1640 | 2290 | 1 |
3 x B2250 | 675 | 960 | 2305 | 3280 | 1 |
4 x B2250 | 905 | 1295 | 3090 | 4420 | 1 |
1 x B2250 | 305 | 420 | 1045 | 1435 | 2 |
2 x B2250 | 500 | 695 | 1710 | 2375 | 2 |
3 x B2250 | 695 | 950 | 2375 | 3245 | 2 |
4 x B2250 | 900 | 1235 | 3075 | 4215 | 2 |
AC platform power consumption (high-line input)
The actual amount of power draw from the AC source depends on the type and number of blades, as well as the power supply AC source voltage, and redundancy configuration. This table shows possible configurations for high-line input, and the typical and maximum AC mains power draw.
Blade quantity and type | Typical system power draw (W) | Maximum system power draw (W) | Typical system heat (BTU/hr) | Maximum system heat (BTU/hr) | Number of power supplies installed |
---|---|---|---|---|---|
Chassis only | < 100 | < 100 | < 340 | < 340 | 1 or 2 |
1 x B2100 | 250 | 360 | 855 | 1230 | 1 |
2 x B2100 | 430 | 605 | 1470 | 2065 | 1 |
3 x B2100 | 610 | 850 | 2085 | 2905 | 1 |
4 x B2100 | 800 | 1090 | 2730 | 3720 | 1 |
1 x B2100 | 280 | 385 | 960 | 1315 | 2 |
2 x B2100 | 460 | 625 | 1570 | 2135 | 2 |
3 x B2100 | 635 | 860 | 2170 | 2935 | 2 |
4 x B2100 | 820 | 1095 | 2800 | 3740 | 2 |
1 x B2150 | 250 | 360 | 855 | 1230 | 1 |
2 x B2150 | 430 | 605 | 1470 | 2065 | 1 |
3 x B2150 | 610 | 850 | 2085 | 2905 | 1 |
4 x B2150 | 800 | 1090 | 2730 | 3720 | 1 |
1 x B2150 | 280 | 385 | 960 | 1315 | 2 |
2 x B2150 | 460 | 625 | 1570 | 2135 | 2 |
3 x B2150 | 635 | 860 | 2170 | 2935 | 2 |
4 x B2150 | 820 | 1095 | 2800 | 3740 | 2 |
1 x B2250 | 270 | 395 | 925 | 1350 | 1 |
2 x B2250 | 480 | 665 | 1640 | 2270 | 1 |
3 x B2250 | 675 | 970 | 2305 | 3310 | 1 |
4 x B2250 | 905 | 1245 | 3090 | 4250 | 1 |
1 x B2250 | 305 | 415 | 1045 | 1420 | 2 |
2 x B2250 | 500 | 690 | 1710 | 2355 | 2 |
3 x B2250 | 700 | 955 | 2390 | 3260 | 2 |
4 x B2250 | 900 | 1245 | 3075 | 4250 | 2 |
DC power requirements
When working with a DC-powered VIPRION® 2400 platform, it is important to understand the DC power options and requirements.
The platform supports up to two hot swappable DC power supplies. One power supply powers a chassis that contains zero to four blades, with no redundancy. Two power supplies power a chassis with any blade configuration, with full redundancy.
DC platform power consumption
The actual amount of power draw from the DC power source depends on the type and number of blades, and the redundancy configuration. This table shows several possible configurations, and the typical and maximum power draw.
Blade quantity and type | Typical system power draw (W) | Maximum system power draw (W) | Typical system heat (BTU/hr) | Maximum system heat (BTU/hr) | Number of power supplies installed |
---|---|---|---|---|---|
Chassis only | < 100 | < 100 | < 340 | < 340 | 1 or 2 |
1 x B2100 | 240 | 335 | 820 | 1145 | 1 |
2 x B2100 | 415 | 555 | 1420 | 1895 | 1 |
3 x B2100 | 595 | 830 | 2035 | 2835 | 1 |
4 x B2100 | 775 | 1085 | 2645 | 3705 | 1 |
1 x B2100 | 255 | 355 | 875 | 1215 | 2 |
2 x B2100 | 430 | 585 | 1470 | 2000 | 2 |
3 x B2100 | 605 | 825 | 2065 | 2820 | 2 |
4 x B2100 | 785 | 1060 | 2680 | 3620 | 2 |
1 x B2150 | 240 | 335 | 820 | 1145 | 1 |
2 x B2150 | 415 | 555 | 1420 | 1895 | 1 |
3 x B2150 | 595 | 830 | 2035 | 2835 | 1 |
4 x B2150 | 775 | 1085 | 2645 | 3705 | 1 |
1 x B2150 | 255 | 355 | 875 | 1215 | 2 |
2 x B2150 | 430 | 585 | 1470 | 2000 | 2 |
3 x B2150 | 605 | 825 | 2065 | 2820 | 2 |
4 x B2150 | 785 | 1060 | 2680 | 3620 | 2 |
1 x B2250 | 255 | 370 | 875 | 1265 | 1 |
2 x B2250 | 450 | 640 | 1540 | 2185 | 1 |
3 x B2250 | 645 | 915 | 2205 | 3125 | 1 |
4 x B2250 | 840 | 1215 | 2870 | 4150 | 1 |
1 x B2250 | 270 | 385 | 925 | 1315 | 2 |
2 x B2250 | 465 | 640 | 1590 | 2185 | 2 |
3 x B2250 | 665 | 895 | 2270 | 3055 | 2 |
4 x B2250 | 850 | 1200 | 2905 | 4095 | 2 |
Safety requirements
This equipment complies with these safety requirements of the Low Voltage Directive 2006/95/EC.
EC Type Examination Certificates: | ||
EN 60950-1:2006 + A11:2009 | ||
IEC 60950-1:2005, 2nd Edition | ||
CB Scheme | ||
UL 60950-1 2nd Edition, CSA C22.2 No. 60950-1-07 | Master Contract: 252302 |
EMC requirements
USA--FCC Class A, Canada--Industry Canada Class A
This equipment complies with Subpart B of Part 15 of FCC Rules for Class A digital devices, Industry Canada ICES-003, Issue 5. Operation is subject to these two conditions:
- This equipment may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
European Union
This equipment complies with these requirements of the EMC Directive 2004/108/EC:
As Telecommunication Network Equipment (TNE) in Both Telecom Centers and Other than Telecom Centers per (as applicable):
Directive | Required Limits | |
---|---|---|
EN 300 386 V1.5.1 2010 | ||
EN 55022:2006 + C1:2006 | Class A | |
EN 61000-3-2:2006 A1:2009 + A2:2009 | ||
EN 61000-3-3:2008 | ||
IEC 61000-4-2 | 6 kV (Direct), 8 kV (Air) | |
IEC 61000-4-3 | 3 V/m 80-1000MHz, 10 V/m 800-960 MHz and 1400-2700 MHz | |
IEC 61000-4-4 | 1 kV AC and DC Power Lines, 0.5 kV Signal Lines | |
IEC 61000-4-5 | 2 kV AC Line-Gnd, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor Signal Lines > 10m. | |
IEC 61000-4-6 | 3 V | |
IEC 61000-4-11 |
As Information Technology Equipment (ITE) Class A per (as applicable):
Directive | Required Limits | |
---|---|---|
EN 55024:2010 | ||
EN 55022:2010 | Class A | |
EN 61000-3:2008 | ||
EN 55024:2010 | ||
IEC61000-4-2 | 4 kV (Direct), 8 kV (Air) | |
IEC61000-4-3 | 3 V/m | |
IEC61000-4-4 | 1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines | |
IEC61000-4-5 | 2 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines | |
IEC61000-4-6 | 3 V | |
IEC61000-4-11 |
Acoustic, airflow, and altitude specifications
This table lists acoustic levels, airflow movement, and operational altitude specifications for the VIPRION® 2400 platform.
Specification type | Detail | Units | Chassis with blade |
---|---|---|---|
Maximum acoustic output 1 | Front
Left Right Rear |
dBA
dBA dBA dBA |
75
71 72 81 |
Altitude 2 |
Operational Non-operational |
Feet Feet |
6000 40,000 |
Airflow 3 | Entire chassis | CFM | 581 |