Applies To:
Show Versions
BIG-IP AAM
- 14.1.0, 14.0.0, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP APM
- 15.1.0, 15.0.1, 15.0.0, 14.1.2, 14.1.0, 14.0.1, 14.0.0, 13.1.3, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP GTM
- 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP Analytics
- 15.1.0, 15.0.1, 15.0.0, 14.1.2, 14.1.0, 14.0.1, 14.0.0, 13.1.3, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP Link Controller
- 15.1.0, 15.0.1, 15.0.0, 14.1.2, 14.1.0, 14.0.1, 14.0.0, 13.1.3, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP LTM
- 15.1.0, 15.0.1, 15.0.0, 14.1.2, 14.1.0, 14.0.1, 14.0.0, 13.1.3, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP AFM
- 15.1.0, 15.0.1, 15.0.0, 14.1.2, 14.1.0, 14.0.1, 14.0.0, 13.1.3, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP PEM
- 15.1.0, 15.0.1, 15.0.0, 14.1.2, 14.1.0, 14.0.1, 14.0.0, 13.1.3, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
BIG-IP DNS
- 15.1.0, 15.0.1, 15.0.0, 14.1.2, 14.1.0, 14.0.1, 14.0.0, 13.1.3, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0
BIG-IP ASM
- 15.1.0, 15.0.1, 15.0.0, 14.1.2, 14.1.0, 14.0.1, 14.0.0, 13.1.3, 13.1.1, 13.1.0, 13.0.1, 13.0.0, 12.1.4, 12.1.3, 12.1.2, 12.1.1, 12.1.0, 11.6.4, 11.6.3, 11.6.2, 11.6.1, 11.5.9, 11.5.8, 11.5.7, 11.5.6, 11.5.5, 11.5.4, 11.5.3, 11.5.2, 11.5.1
Platform Specifications
General specifications for system features
This table lists general specifications for system features for the 5000 Series platform.
Item | Specification |
---|---|
Transceiver modules hot swap | Support for hot swap of SFP, SFP+, and QSFP+ transceiver modules |
Power supply hot swap | Support for hot swap of the power supplies |
Jumbo frames | Support for maximum Ethernet frame size of 9216 bytes and MTU of 9128 bytes |
Virtual Clustered Multiprocessing™ (vCMP™) | Supports provisioning and managing multiple, hosted instances of the BIG-IP software on a single hardware device |
Platform hardware specifications
This table lists hardware specifications for the 5000 Series platform.
Item | Specification |
---|---|
Dimensions | H: 1.75 inches (4.45 cm) x W: 17.0 inches (43.18 cm) x D: 21.0 inches (53.34 cm) (per unit) 1U industry standard rack-mount chassis |
Weight | 21.0 pounds (9.53 kg) with one power supply (per unit)
23.5 pounds (10.66 kg) with two power supplies (per unit)
|
Processor | 1 x Quad-Core Intel® Xeon® processor |
Communication interfaces | 4 x 1GbE Cu RJ45 ports
8 x 10GbE SFP+ ports 1 x 10/100/1000 Ethernet Management port 1 x RJ45 console port 1 x RJ45 failover port 2 x USB 2.0 interfaces |
Hard drive capacity | 1 x 1 TB hard disk drive (HDD) OR
1 x 400 GB solid-state drive (SSD) (5050 Series platform only) |
RAM | 32 GB |
AC power input requirements | 1-2 x 400 W 90-240VAC, 50-60hz |
DC power supply | 1-2 x 300 W DC
Operating range: 40 to 72 VDC |
Platform environmental operating specifications
This table lists platform environmental operating specifications.
Item | Specification |
---|---|
Operational temperature | 32 to 104°F (0 to 40°C) |
Operational relative humidity | GR-63-CORE table 4-4
5% to 85% (40°C) non-condensing 5% to 90% (40°C) non-condensing for a maximum of |
Non-operational temperature | -40 to 158°F (-40 to 70°C) |
Non-operational relative humidity | 5 to 95% (40°C) non-condensing |
5000s/5200v platform power specifications
This table lists power specifications for the 5000s/5200v platforms.
Item | Single Power Supply | Dual Power Supply |
---|---|---|
Typical power draw (AC power; 50% load; temp 25°C) | 110VAC input: 165W 220VAC input: 165W |
110VAC input: 175W 220VAC input: 175W |
Typical power draw (DC power; 50% load; temp 25°C) | 48VDC input: 195W | 48VDC input: 200W |
Maximum power draw (AC power) | 90VAC input: 245W | 90VAC input: 260W |
Maximum power draw (DC power) | 40VDC input: 260W | 40VDC input: 265W |
Typical heat generated (AC power) | 110VAC input: 564 BTU/hour 220VAC input: 564 BTU/hour |
110VAC input: 598 BTU/hour 220VAC input: 598 BTU/hour |
Typical heat generated (DC power) | 48VDC input: 666 BTU/hour | 48VDC input: 683 BTU/hour |
Maximum heat generated (AC power) | 90VAC input: 836 BTU/hour | 90VAC input: 888 BTU/hour |
Maximum heat generated (DC power) | 40VDC input: 888 BTU/hour | 40VDC input: 905 BTU/hour |
5050 Series platform power specifications
This table lists power specifications for the 5050 Series platform.
Item | Single Power Supply | Dual Power Supply |
---|---|---|
Typical power draw (AC power; 50% load; temp 25°C) | 110VAC input: 175W 220VAC input: 175W |
110VAC input: 185W 220VAC input: 185W |
Typical power draw (DC power; 50% load; temp 25°C) | 48VDC input: 200W | 48VDC input: 210W |
Maximum power draw (AC power) | 90VAC input: 255W | 90VAC input: 270W |
Maximum power draw (DC power) | 40VDC input: 270W | 40VDC input: 275W |
Typical heat generated (AC power) | 110VAC input: 595 BTU/hour 220VAC input: 595 BTU/hour |
110VAC input: 630 BTU/hour 220VAC input: 630 BTU/hour |
Typical heat generated (DC power) | 48VDC input: 680 BTU/hour | 48VDC input: 715 BTU/hour |
Maximum heat generated (AC power) | 90VAC input: 870 BTU/hour | 90VAC input: 920 BTU/hour |
Maximum heat generated (DC power) | 40VDC input: 920 BTU/hour | 40VDC input: 940 BTU/hour |
Safety requirements
This equipment complies with these requirements of the Low Voltage Directive 2006/95/EC:
EC Type Examination Certificates: | Master Contract 252302 | |
CB Scheme | ||
EN 60950-1:2006+A11:2009+A1:2010+A12:2011 | ||
IEC 60950-1:2005, A1:2009 | ||
CSA 60950-1-07, Including Amendment 1:2011 | ||
ANSI/UL 60950-1-2011 |
EMC requirements
USA--FCC Class A, Canada--Industry Canada Class A
This equipment complies with Subpart B of Part 15 of FCC Rules for Class A digital devices, Industry Canada ICES-003, Issue 5. Operation is subject to these two conditions:
- This equipment may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
European Union
This equipment complies with these requirements of the EMC Directive 2004/108/EC:
As Telecommunication Network Equipment (TNE) in Both Telecom Centers and Other than Telecom Centers per (as applicable): | ||
Directive | Required Limits | |
EN | 300 386 V1.5.1 (2010-10) | |
EN | 55022:2010 | Class A |
EN | 61000-3-2:2006+A1:2009+A2:2009 | |
EN | 61000-3-3:2008 | |
EN | 55024:2010 | |
IEC61000-4-2 | 6 kV (Direct), 8 kV (Air) | |
IEC61000-4-3 | 3 V/m 80-1000MHz, 10 V/m 800-960 MHz and 1400-2700 MHz | |
IEC61000-4-4 | 1 kV AC and DC Power Lines, 0.5 kV Signal Lines | |
IEC61000-4-5 | 2 kV AC Line-Gnd, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor Signal Lines > 10m | |
IEC61000-4-6 | 3 V | |
IEC61000-4-8 | ||
IEC61000-4-11 |
As Information Technology Equipment (ITE) Class A per (as applicable): | ||
EN | 55022:2010 | Class A |
EN | 61000-3-3:2008 | |
EN | 55024:2010 | |
IEC61000-4-2 | 4 kV (Direct), 8 kV (Air) | |
IEC61000-4-3 | 3 V/m | |
IEC61000-4-4 | 1 kV AC Power Lines, 0.5 kV Signal, and DC Power Lines | |
IEC61000-4-5 | 1 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines | |
IEC61000-4-6 | 3 V | |
IEC61000-4-8 | ||
IEC61000-4-11 |
Acoustic, airflow, and altitude specifications
This table lists acoustic levels, airflow movement, and operational altitude specifications for the 5000 Series platform.
Specification type | Detail | Units | Value |
---|---|---|---|
Acoustic 1 | Front
Back Left Right Top |
dBA
dBA dBA dBA dBA |
63 71 61 62 64 |
Altitude 2 | Operational
Non-operational |
Feet (Meters)
Feet (Meters) |
6,000 (1,829)
40,000 (12,192) |
Airflow 3 | Open air | CFM | 94.8 |