Manual Chapter : Configure an NSH-aware service function of type Virtual

Applies To:

  • BIG-IP LTM

    21.0.0, 17.5.1, 17.5.0, 17.1.3, 17.1.2, 17.1.1, 17.1.0, 17.0.0, 16.1.6, 16.1.5, 16.1.4, 16.1.3, 16.1.2, 16.1.1, 16.1.0, 16.0.1, 16.0.0, 15.1.10, 15.1.9, 15.1.8, 15.1.7, 15.1.6, 15.1.5, 15.1.4, 15.1.3, 15.1.2, 15.1.1, 15.1.0, 15.0.1, 15.0.0, 14.1.5, 14.1.4, 14.1.3, 14.1.2, 14.1.0, 14.0.1, 14.0.0

Configure an NSH-aware service function of type Virtual

Each SFF has some number of service functions (SF) associated with it. A service function is the service on a device that processes requests from, and sends responses to, an SFF in a service chain. You must associate a n NSH-aware service function of type Virtual with an SFF.

Note: Unlike the other SFs in the sample configuration, this SF resides directly on its associated SFF.

  1. From the SFC controller menu on the left side of the screen, select Service Functions.

  2. In the upper left corner, click Create.

    The Create New Service Function screen opens.

  3. Type a unique name for the SF.

    In our sample configuration, this is sf2-2.

  4. From the Service Function Forwarder list, select an SFF.

    In our sample configuration, this is sff2.

  5. From the NSH Aware list, select Yes.

  6. From the Resource Type list, select Virtual.

  7. From theVirtual Server list, select the virtual server that you created as a prerequisite for this SF.

  8. Click Create.

    After you complete this step, the SFC controller propagates the SF configuration data you entered to the relevant SFF.

After completing this task, you have configured an NSH-aware SF of type Virtual. This is the second of the two NSH-aware SFs in the sample configuration.