Manual Chapter : Platform Specifications

Applies To:

Show Versions Show Versions

F5OS-A

  • 1.8.0, 1.7.0, 1.3.1, 1.3.0, 1.2.0, 1.1.1, 1.1.0
Manual Chapter

Platform Specifications

General specifications for system features

This table lists general specifications for system features for
rSeries
platforms.
Item
Specification
Transceiver modules hot swap
Support for hot swap of optical transceiver modules
Power supply unit hot swap
Support for hot swap of the power supply units (PSUs) in dual supply systems
Jumbo frames
Support for maximum Ethernet frame size of 9216 bytes and MTU of 9128 bytes

Hardware specifications - r2000 Series

This table lists hardware specifications for r2000 Series platforms.
Item
Specification
Dimensions
H: 1.72 inches (4.37 cm) x W: 17.1 inches (43.43 cm) x D: 18.70 inches (47.50 cm) (per unit) 1U industry standard rack-mount chassis
Weight
20.0 pounds (9.07 kg) with one power supply unit (per unit)
  • Quick install rail kit adds 4.5 pounds (2.04 kg).
  • Optional front-mount rack brackets add 2.5 pounds (1.13 kg).
  • Additional power supply unit adds 2.0 pounds (0.91 kg).
Processor
1 x Eight-Core Intel® Atom® processor
Communication interfaces
4 x 25G/10G/1G SFP+/SFP28/SFP ports
4 x 10G/1G RJ45 ports
1 x 1000Base-T management port
1 x RJ45 serial console port
1 x USB 3.0 interface
Storage drive capacity
1 x 480 GB M.2 solid-state drive (SSD)
Memory
32 GB
AC power supply unit
1 to 2 x 250W AC; 100-240 VAC, 50/60 Hz, 5 A per cord x 2 (max 5 A total)
1 x universal power cords
DC power supply unit
1 to 2 x 650W DC; -48 to -60 VDC, 6 A per cord (max 6 A total) or 220 to 380 VDC, 4 A per cord (max 4 A total)
Operating range: 44-72 VDC
Minimum start up voltage: 44 VDC
power supply unit will not start below 44 VDC.
Specifications are subject to change without notification.

Hardware specifications - r4000 Series

This table lists hardware specifications for r4000 Series platforms.
Item
Specification
Dimensions
H: 1.72 inches (4.37 cm) x W: 17.1 inches (43.43 cm) x D: 18.70 inches (47.50 cm) (per unit) 1U industry standard rack-mount chassis
Weight
20.0 pounds (9.07 kg) with one power supply unit (per unit)
  • Quick install rail kit adds 4.5 pounds (2.04 kg).
  • Optional front-mount rack brackets add 2.5 pounds (1.13 kg).
  • Additional power supply unit adds 2.0 pounds (0.91 kg).
Processor
1 x 16-Core Intel® Atom® processor
Communication interfaces
4 x 25G/10G/1G SFP+/SFP28/SFP ports
4 x 10G/1G RJ45 ports
1 x 1000Base-T management port
1 x RJ45 serial console port
1 x USB 3.0 interface
Storage drive capacity
1 x 480 GB M.2 solid-state drive (SSD)
Memory
64 GB
AC power supply unit
1 to 2 x 250W AC; 100-240 VAC, 50/60 Hz, 5 A per cord x 2 (max 5 A total)
1 x universal power cords
DC power supply unit
1 to 2 x 650W DC; -48 to -60 VDC, 6 A per cord (max 6 A total) or 220 to 380 VDC, 4 A per cord (max 4 A total)
Operating range: 44-72 VDC
Minimum start up voltage: 44 VDC
power supply unit will not start below 44 VDC.
Specifications are subject to change without notification.

Power specifications - r2000 Series

This table lists power specifications for r2000 Series platforms.

650W power supply unit (PSU)

Item
Single PSU
Dual PSU
Idle power draw (AC power)
110VAC input: 75W
230VAC input: 75W
110VAC input: 85W
230VAC input: 85W
Idle power draw (DC
/HVDC
power)
53DC input: 75W
240HVDC input: 350W
53DC input: 85W
240HVDC input: 360W
Typical power draw (AC power; 50% load; temp 25°C)
110VAC input: 95W
230VAC input: 95W
110VAC input: 110W
230VAC input: 105W
Typical power draw (DC
/HVDC
power; 50% load; temp 25°C)
53DC input: 95W
240VDC input: 95W
53DC input: 110W
240VDC input: 105W
Maximum power draw (AC power)
110VAC input: 115W
230VAC input: 115W
110VAC input: 130W
230VAC input: 125W
Maximum power draw (DC
/HVDC
power)
53DC input: 115W
240HVDC input: 115W
53DC input: 130W
240HVDC input: 125W
Typical heat generated (AC power)
110VAC input: 325 BTU/hour
230VAC input: 325 BTU/hour
110VAC input: 380 BTU/hour
230VAC input: 360 BTU/hour
Typical heat generated (DC
/HVDC
power)
53DC input: 325 BTU/hour
240HVDC input: 325 BTU/hour
53DC input: 380 BTU/hour
240HVDC input: 360 BTU/hour
Maximum heat generated (AC power)
110VAC input: 395 BTU/hour
230VAC input: 395 BTU/hour
110VAC input: 445 BTU/hour
230VAC input: 430 BTU/hour
Maximum heat generated (DC
/HVDC
power)
53DC input: 395 BTU/hour
240HVDC input: 395 BTU/hour
53DC input: 430 BTU/hour
240HVDC input: 430 BTU/hour

250W power supply unit (PSU)

Item
Single PSU
Dual PSU
Idle power draw (AC power)
110VAC input: 65W
230VAC input: 65W
110VAC input: 75W
230VAC input: 70W
Typical power draw (AC power; 50% load; temp 25°C)
110VAC input: 85W
230VAC input: 85W
110VAC input: 95W
230VAC input: 90W
Maximum power draw (AC power)
110VAC input: 105W
230VAC input: 105W
110VAC input: 110W
230VAC input: 110W
Typical heat generated (AC power)
110VAC input: 295 BTU/hour
230VAC input: 295 BTU/hour
110VAC input: 325 BTU/hour
230VAC input: 310 BTU/hour
Maximum heat generated (AC power)
110VAC input: 360 BTU/hour
230VAC input: 360 BTU/hour
110VAC input: 380 BTU/hour
230VAC input: 380 BTU/hour
Specifications are subject to change without notification.

Power specifications - r4000 Series

This table lists power specifications for r4000 Series platforms.

650W power supply unit (PSU)

Item
Single PSU
Dual PSU
Idle power draw (AC power)
110VAC input: 80W
230VAC input: 80W
110VAC input: 90W
230VAC input: 95W
Idle power draw (DC
/HVDC
power)
53DC input: 80W
240HVDC input: 80W
53DC input: 90W
240HVDC input: 90W
Typical power draw (AC power; 50% load; temp 25°C)
110VAC input: 110W
230VAC input: 110W
110VAC input: 120W
230VAC input: 125W
Typical power draw (DC
/HVDC
power; 50% load; temp 25°C)
53DC input: 100W
240VDC input: 110W
53DC input: 105W
240VDC input: 120W
Maximum power draw (AC power)
110VAC input: 135W
230VAC input: 135W
110VAC input: 150W
230VAC input: 150W
Maximum power draw (DC
/HVDC
power)
53DC input: 135W
240HVDC input: 135W
53DC input: 150W
240HVDC input: 145W
Typical heat generated (AC power)
110VAC input: 380 BTU/hour
230VAC input: 345 BTU/hour
110VAC input: 410 BTU/hour
230VAC input: 360 BTU/hour
Typical heat generated (DC
/HVDC
power)
53DC input: 380 BTU/hour
240HVDC input: 380 BTU/hour
53DC input: 410 BTU/hour
240HVDC input: 410 BTU/hour
Maximum heat generated (AC power)
110VAC input: 465 BTU/hour
230VAC input: 445 BTU/hour
110VAC input: 515 BTU/hour
230VAC input: 445 BTU/hour
Maximum heat generated (DC
/HVDC
power)
53DC input: 465 BTU/hour
240HVDC input: 465 BTU/hour
53DC input: 495 BTU/hour
240HVDC input: 495 BTU/hour

250W power supply unit (PSU)

Item
Single PSU
Dual PSU
Idle power draw (AC power)
110VAC input: 70W
230VAC input: 70W
110VAC input: 80W
230VAC input: 80W
Typical power draw (AC power; 50% load; temp 25°C)
110VAC input: 105W
230VAC input: 100W
110VAC input: 110W
230VAC input: 105W
Maximum power draw (AC power)
110VAC input: 135W
230VAC input: 130W
110VAC input: 135W
230VAC input: 130W
Typical heat generated (AC power)
110VAC input: 360 BTU/hour
230VAC input: 345 BTU/hour
110VAC input: 380 BTU/hour
230VAC input: 360 BTU/hour
Maximum heat generated (AC power)
110VAC input: 465 BTU/hour
230VAC input: 445 BTU/hour
110VAC input: 465 BTU/hour
230VAC input: 445 BTU/hour
Specifications are subject to change without notification.

Environmental operating specifications

This table lists platform environmental operating specifications.
Item
Specification
Operational temperature
32 to 104°F (0 to 40°C)
Operational relative humidity
5% to 85% (40°C) non-condensing
Up to 93% (40°C) non-condensing for a maximum of 96 hours
Non-operational temperature
-40 to 158°F (-40 to 70°C)
Non-operational relative humidity
5% to 93% (40°C) non-condensing

Acoustic and altitude specifications

This table lists acoustic levels and operational altitude specifications for
F5
rSeries
platforms.
Specification type
Detail
Value
Notes
Acoustic
Sound power
79.87 dBA
A-weighted Sound Power at 27°C full system load. Declared A weighted 82.87
Altitude
Operational
6,000 Feet
Per Telcordia GR-63-CORE, section 4.1.3: This unit is functional when installed at elevations between 60m (197 feet) below sea level and 1800m (6000 feet) above sea level at the aisle ambient temperatures of 40°C.
Non-operational
40,000 Feet

Airflow specifications

This table lists airflow movement specifications for
F5
r2000/r4000 Series
platforms.
Fan tray airflow measurements are taken at 100% duty cycle and in open air.
Platform
Value (max)
r2000/r4000
92 CFM