Manual Chapter :
Platform Specifications
Applies To:
Show VersionsF5OS-A
- 1.8.0, 1.7.0, 1.3.1, 1.3.0, 1.2.0, 1.1.1, 1.1.0
Platform Specifications
General specifications for system features
This table lists general specifications for system features for
rSeries
platforms.Item | Specification |
---|---|
Transceiver modules hot swap | Support for hot swap of optical transceiver modules |
Power supply unit hot swap | Support for hot swap of the power supply units (PSUs) in dual supply systems |
Jumbo frames | Support for maximum Ethernet frame size of 9216 bytes and MTU of 9128 bytes |
Hardware specifications - r2000 Series
This table lists hardware specifications for r2000 Series platforms.
Item | Specification |
---|---|
Dimensions | H: 1.72 inches (4.37 cm) x W: 17.1 inches
(43.43 cm) x D: 18.70 inches (47.50 cm) (per unit) 1U industry
standard rack-mount chassis |
Weight | 20.0 pounds (9.07 kg) with one power supply unit (per unit)
|
Processor | 1 x Eight-Core Intel® Atom® processor |
Communication interfaces | 4 x 25G/10G/1G SFP+/SFP28/SFP ports 4 x 10G/1G RJ45 ports 1 x 1000Base-T management port 1 x RJ45 serial console port 1 x USB 3.0 interface |
Storage drive capacity | 1 x 480 GB M.2 solid-state drive (SSD) |
Memory | 32 GB |
AC power supply unit | 1 to 2 x 250W AC; 100-240 VAC, 50/60 Hz, 5 A per cord x 2 (max 5 A total) 1 x universal power cords |
DC power supply unit | 1 to 2 x 650W DC; -48 to -60 VDC, 6 A per cord (max 6 A total) or 220 to 380 VDC, 4 A per cord (max 4 A total) Operating range: 44-72 VDC Minimum start up voltage: 44 VDC power supply unit will not start below 44 VDC. |
Specifications are subject to change without notification.
Hardware specifications - r4000 Series
This table lists hardware specifications for r4000 Series platforms.
Item | Specification |
---|---|
Dimensions | H: 1.72 inches (4.37 cm) x W: 17.1 inches (43.43 cm) x D: 18.70 inches (47.50 cm) (per unit) 1U industry standard rack-mount chassis |
Weight | 20.0 pounds (9.07 kg) with one power supply unit (per unit)
|
Processor | 1 x 16-Core Intel® Atom® processor |
Communication interfaces | 4 x 25G/10G/1G SFP+/SFP28/SFP ports 4 x 10G/1G RJ45 ports 1 x 1000Base-T management port 1 x RJ45 serial console port 1 x USB 3.0 interface |
Storage drive capacity | 1 x 480 GB M.2 solid-state drive (SSD) |
Memory | 64 GB |
AC power supply unit | 1 to 2 x 250W AC; 100-240 VAC, 50/60 Hz, 5 A per cord x 2 (max 5 A total) 1 x universal power cords |
DC power supply unit | 1 to 2 x 650W DC; -48 to -60 VDC, 6 A per cord (max 6 A total) or 220 to 380 VDC, 4 A per cord (max 4 A total) Operating range: 44-72 VDC Minimum start up voltage: 44 VDC power supply unit will not start below 44 VDC. |
Specifications are subject to change without notification.
Power specifications - r2000
Series
This table lists power specifications for r2000
Series platforms.
650W power supply unit (PSU)
Item |
Single PSU |
Dual PSU |
---|---|---|
Idle power draw (AC
power) |
110VAC input: 75W 230VAC input:
75W |
110VAC input: 85W 230VAC input:
85W |
Idle power draw (DC /HVDC
power) |
53DC input: 75W 240HVDC input: 350W |
53DC input: 85W 240HVDC input: 360W |
Typical power draw (AC power;
50% load; temp 25°C) |
110VAC input: 95W 230VAC input:
95W |
110VAC input: 110W 230VAC
input: 105W |
Typical power draw (DC /HVDC power;
50% load; temp 25°C) |
53DC input: 95W 240VDC input: 95W |
53DC input: 110W 240VDC input: 105W |
Maximum power draw (AC
power) |
110VAC input: 115W 230VAC
input: 115W |
110VAC input: 130W 230VAC
input: 125W |
Maximum power draw (DC /HVDC
power) |
53DC input: 115W 240HVDC input: 115W |
53DC input: 130W 240HVDC input: 125W |
Typical heat generated (AC
power) |
110VAC input: 325 BTU/hour 230VAC input: 325 BTU/hour |
110VAC input: 380 BTU/hour 230VAC input: 360 BTU/hour |
Typical heat generated (DC /HVDC
power) |
53DC input: 325 BTU/hour 240HVDC input: 325
BTU/hour |
53DC input: 380 BTU/hour 240HVDC input: 360
BTU/hour |
Maximum heat generated (AC
power) |
110VAC input: 395 BTU/hour 230VAC input: 395
BTU/hour |
110VAC input: 445 BTU/hour 230VAC input: 430
BTU/hour |
Maximum heat generated (DC /HVDC
power) |
53DC input: 395 BTU/hour 240HVDC input: 395
BTU/hour |
53DC input: 430 BTU/hour 240HVDC input: 430
BTU/hour |
250W power supply unit (PSU)
Item |
Single PSU |
Dual PSU |
---|---|---|
Idle power draw (AC
power) |
110VAC input: 65W 230VAC input:
65W |
110VAC input: 75W 230VAC input:
70W |
Typical power draw (AC power;
50% load; temp 25°C) |
110VAC input: 85W 230VAC input:
85W |
110VAC input: 95W 230VAC input:
90W |
Maximum power draw (AC
power) |
110VAC input: 105W 230VAC
input: 105W |
110VAC input: 110W 230VAC
input: 110W |
Typical heat generated (AC
power) |
110VAC input: 295 BTU/hour 230VAC input: 295 BTU/hour |
110VAC input: 325 BTU/hour 230VAC input: 310 BTU/hour |
Maximum heat generated (AC
power) |
110VAC input: 360 BTU/hour 230VAC input: 360
BTU/hour |
110VAC input: 380 BTU/hour 230VAC input: 380
BTU/hour |
Specifications are subject to change without notification.
Power specifications - r4000
Series
This table lists power specifications for r4000
Series platforms.
650W power supply unit (PSU)
Item |
Single PSU |
Dual PSU |
---|---|---|
Idle power draw (AC
power) |
110VAC input: 80W 230VAC input: 80W |
110VAC input: 90W 230VAC input: 95W |
Idle power draw (DC /HVDC
power) |
53DC input: 80W 240HVDC input: 80W |
53DC input: 90W 240HVDC input: 90W |
Typical power draw (AC power;
50% load; temp 25°C) |
110VAC input: 110W 230VAC input: 110W |
110VAC input: 120W 230VAC input: 125W |
Typical power draw (DC /HVDC power;
50% load; temp 25°C) |
53DC input: 100W 240VDC input:
110W |
53DC input: 105W 240VDC input:
120W |
Maximum power draw (AC
power) |
110VAC input: 135W 230VAC input: 135W |
110VAC input: 150W 230VAC input: 150W |
Maximum power draw (DC /HVDC
power) |
53DC input: 135W 240HVDC input:
135W |
53DC input: 150W 240HVDC input:
145W |
Typical heat generated (AC
power) |
110VAC input: 380 BTU/hour 230VAC input: 345 BTU/hour |
110VAC input: 410 BTU/hour 230VAC input: 360 BTU/hour |
Typical heat generated (DC /HVDC
power) |
53DC input: 380 BTU/hour 240HVDC input: 380
BTU/hour |
53DC input: 410 BTU/hour 240HVDC input: 410
BTU/hour |
Maximum heat generated (AC
power) |
110VAC input: 465 BTU/hour 230VAC input: 445
BTU/hour |
110VAC input: 515 BTU/hour 230VAC input: 445
BTU/hour |
Maximum heat generated (DC /HVDC
power) |
53DC input: 465 BTU/hour 240HVDC input: 465
BTU/hour |
53DC input: 495 BTU/hour 240HVDC input: 495
BTU/hour |
250W power supply unit (PSU)
Item |
Single PSU |
Dual PSU |
---|---|---|
Idle power draw (AC
power) |
110VAC input: 70W 230VAC input: 70W |
110VAC input: 80W 230VAC input: 80W |
Typical power draw (AC power;
50% load; temp 25°C) |
110VAC input: 105W 230VAC
input: 100W |
110VAC input: 110W 230VAC
input: 105W |
Maximum power draw (AC
power) |
110VAC input: 135W 230VAC input: 130W |
110VAC input: 135W 230VAC input: 130W |
Typical heat generated (AC
power) |
110VAC input: 360 BTU/hour 230VAC input: 345 BTU/hour |
110VAC input: 380 BTU/hour 230VAC input: 360 BTU/hour |
Maximum heat generated (AC
power) |
110VAC input: 465 BTU/hour 230VAC input: 445
BTU/hour |
110VAC input: 465 BTU/hour 230VAC input: 445
BTU/hour |
Specifications are subject to change without notification.
Environmental operating
specifications
This table lists platform environmental operating
specifications.
Item |
Specification |
---|---|
Operational temperature |
32 to 104°F (0 to 40°C) |
Operational relative humidity |
5% to 85% (40°C) non-condensing Up to 93% (40°C) non-condensing for a maximum of 96 hours |
Non-operational temperature |
-40 to 158°F (-40 to 70°C) |
Non-operational relative humidity |
5% to 93% (40°C) non-condensing |
Acoustic and altitude specifications
This table lists acoustic levels and operational
altitude specifications for
F5
rSeries
platforms.Specification type |
Detail |
Value |
Notes |
---|---|---|---|
Acoustic | Sound power | 79.87 dBA | A-weighted Sound Power at 27°C full system load. Declared A
weighted 82.87 |
Altitude |
Operational |
6,000 Feet |
Per Telcordia
GR-63-CORE, section 4.1.3: This unit is functional when
installed at elevations between 60m (197 feet) below sea
level and 1800m (6000 feet) above sea level at the aisle
ambient temperatures of 40°C.
|
Non-operational |
40,000 Feet |
Airflow specifications
This table lists airflow movement specifications for
F5
r2000/r4000 Series
platforms.Fan tray airflow measurements are taken at 100% duty cycle and in open air.
Platform | Value (max) |
---|---|
r2000/r4000 | 92 CFM |