General specifications for system features
This table lists general specifications for system features for BIG-IP® iSeries platforms.
Item | Specification |
---|---|
Transceiver modules hot swap | Support for hot swap of optical transceiver modules |
Power supply hot swap | Support for hot swap of the power supplies |
Jumbo frames | Support for maximum Ethernet frame size of 9216 bytes and MTU of 9128 bytes |
F5®TurboFlex™ Profiles | TurboFlex Profiles are groupings of hardware-accelerated (FPGA) features that are associated with a specific use case. TurboFlex Profiles are groupings of hardware-accelerated features that are dependent on module licensing. If BIG-IP® LTM® is licensed and provisioned, then the ADC profile is available. If BIG-IP AFM™ is licensed and provisioned, then the Security profile is available. TurboFlex Profiles are supported only in platforms running a high performance license (x800). Also, TurboFlex Profile availability varies depending on the platform series tier. |
Hardware specifications - i800 Series
This table lists hardware specifications for i800 Series platforms.
Item | Specification |
---|---|
Dimensions | H: 1.72 inches (4.37 cm) x W: 17.4 inches (44.20 cm) x D: 22.5 inches (57.15 cm) (per unit) 1U industry standard rack-mount chassis |
Weight | 20.0 pounds (9.07 kg) with one power supply (per unit)
|
Processor | 1 x Dual-Core Intel® Xeon® processor (total 4 hyperthreaded logical processing cores) |
Communication interfaces | 2 x 10GbE SFP+
4 x 1GbE SFP ports 1 x 10/100/1000Base-T management port 1 x RJ45 console port 1 x RJ45 failover port 1 x USB 2.0 interface |
Storage drive capacity | 1 x 500 GB Enterprise Class hard disk drive (HDD) |
RAM | 16 GB |
AC power supply | 1 x 250 W 100-240 VAC(+/- 10%) AUTO Switching Platinum
1 x NEMA 5-15P power cords |
Environmental operating specifications
This table lists platform environmental operating specifications.
Item | Specification |
---|---|
Operational temperature | 32 to 104°F (0 to 40°C) |
Operational relative humidity | 5% to 85% (40°C) non-condensing
Up to 93% (40°C) non-condensing for a maximum of |
Non-operational temperature | -40 to 158°F (-40 to 70°C) |
Non-operational relative humidity | 5% to 93% (40°C) non-condensing |
Power specifications - i800 Series
This table lists power specifications for i800 Series platforms.
Item | Single power supply | Dual power supply |
---|---|---|
Idle power draw (AC power) | 110VAC input: 70W 220VAC input: 70W |
110VAC input: 80W 220VAC input: 75W |
Typical power draw (AC power; 50% load; temp 25°C) | 110VAC input: 95W 220VAC input: 95W |
110VAC input: 100W 220VAC input: 100W |
Maximum power draw (AC power) | 110VAC input: 120W 220VAC input: 120W |
110VAC input: 120W 220VAC input: 120W |
Typical heat generated (AC power) | 110VAC input: 325 BTU/hour
220VAC input: 345 BTU/hour |
110VAC input: 325 BTU/hour
220VAC input: 345 BTU/hour |
Maximum heat generated (AC power) | 410 BTU/hour | 410 BTU/hour |
Safety requirements
This equipment complies with these requirements of the Low Voltage Directive 2014/35/EU:
EC Type Examination Certificates: Master Contract 252302 | |
CB Scheme | |
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 | |
IEC 60950-1:2005, A1:2009+A2:2013 | |
CSA 60950-1-07, Including A1:2011+A2:2014 | |
ANSI/UL 60950-1-2014 |
EMC requirements
USA--FCC Class A, Canada--Industry Canada Class A
This equipment complies with Part 15 of FCC Rules. Operation is subject to these two conditions:
- This equipment may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
European Union
This equipment complies with these requirements of the EMC Directive 2014/30/EU:
As Telecommunication Network Equipment (TNE) in Both Telecom Centers and Other than Telecom Centers per (as applicable):
ETSI EN 300 386 V1.6.1 (2012) |
EN 55032:2012/AC:2013 |
EN 61000-3-2:2014 |
EN 61000-3-3:2013 |
As Information Technology Equipment (ITE) Class A per (as applicable):
EN 55024:2010 |
EN 55032:2012/AC:2013 |
EN 61000-3-2:2014 |
EN 61000-3-3:2013 |
Acoustic and altitude specifications
This table lists acoustic levels and operational altitude specifications for iSeries platforms.
Specification type | Detail | Value | Notes |
---|---|---|---|
Acoustic | Sound power | 72.72 dBA | A-weighted Sound Power at 27°C full system load. |
Altitude | Operational | 13,000 Feet | Per BELCORE GR-63-CORE, section 4.1.3: This unit is functional when installed at elevations between 60m (197 feet) below sea level and 1800m (6000 feet) above sea level at the aisle ambient temperatures of 40°C. |
Non-operational | 40,000 Feet |
Restriction of Hazardous Substances Directive (RoHS) for China
Products listed on this declaration comply with the Restriction of Hazardous Substances (RoHS) directive 2011/65/EU, and produce required technical documentation in compliance with EN50581:2012.
In accordance with China's Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products #32, the following information is provided regarding the names and concentration levels of toxic substances or hazardous substances that may be contained in the following product relative to the standards set by the Standardization Administration of the People's Republic of China.