Manual Chapter :
Prepare for Logging Node Upgrade with Minimal Downtime
Applies To:
Show VersionsBIG-IQ Centralized Management
- 5.4.0
Preparing the logging node cluster for upgrade with minimal downtime
If you choose the minimal downtime method, you can upgrade your logging node cluster minimizing the time that the cluster is offline.
Important: You cannot perform the
minimal downtime upgrade unless you have at least 3 logging nodes in your cluster.
Check Logging Node health
You
can use the Logging Configuration screen to review the overall health and status of the
Logging Nodes you've configured. You can use the data displayed on this screen both
before and after an upgrade to verify that your Logging Node cluster configuration is as
you expect it to be.
Note: Perform this check on the BIG-IQ®; not on the Logging
Node.
Confirm disk space is sufficient for upgrade with minimal downtime
As part of preparing to upgrade your
logging node with minimal downtime, you must confirm that there is sufficient disk size
in the cluster so that when you take a logging node offline, there is room for its data
on other devices in the cluster. If the amount of free space in the cluster is less than
the amount of data on any one node, then there is insufficient space to upgrade without
downtime. If this is the case, you need to either add logging nodes or increase storage
space on the existing logging nodes.
If there is sufficient space, you
can proceed. Otherwise, you need to either add logging nodes, or add logging node
storage space.
Confirm that BIG-IP logging node configuration is correct
In preparing to upgrade your logging
node with minimal downtime, you must confirm that the BIG-IP®
device to logging node configuration is correct, so that when a particular logging node
is upgraded, data that was being routed to it is automatically routed to another logging
node in the cluster. There are two settings of particular concern:
- Confirm that data sent from the BIG-IP devices is not being sent to just one logging node. Each BIG-IP device must be configured to send data to multiple logging nodes.
- Confirm that the BIG-IP devices are configured with appropriate monitors that allow for traffic to switch to a different logging node when one logging node is taken offline.
Stop snapshot creation
Because of the mixed software
version environment that occurs during the upgrade process, if snapshot schedules are
configured for the cluster, you should stop creating snapshots before you begin the
upgrade to prevent possible issues with your data.